Diagnostics
Thorough analysis of the hydraulic system condition and fault identification.
Solution Design
Development of an optimal plan, including a price quote.
Repair / Replacement
Professional execution of repairs or replacement of damaged components.
Testing
Complex testing on test bench and setting according to manufacturer specifications.
Test report
Record from the test result + shipment.
Diagnostics
Thorough analysis of the hydraulic system condition and fault identification.
Solution Design
Development of an optimal plan, including a price quote.
Repair / Replacement
Professional execution of repairs or replacement of damaged components.
Testing
Complex testing on test bench and setting according to manufacturer specifications.
Test report
Record from the test result + shipment.
Express Custom Hydraulic Hose Manufacturing
Fast, reliable, and according to your requirements.
How Efficiency Loss Affects Your System?
Worn hydraulic pumps and hydraulic motors lead to power losses and excessive heating. See how the losses compound.
η₁ Pump
92.0%
η₂ Hydraulic Motor
92.0%
Total Efficiency
84.6%
Power Loss
15.4 kW
Heat Loss
15.4 kW
= power loss
All power losses in a hydraulic system are converted to heat, which degrades oil and significantly shortens component lifespan.
Loss Overview by Efficiency Drop
| Efficiency Drop | η Pump | η Hydraulic Motor | Total Efficiency | Power Loss | Heat Loss | Additional |
|---|---|---|---|---|---|---|
| 0% | 92.0% | 92.0% | 84.6% | 15.4 kW | 15.4 kW | — |
| 1% | 91.0% | 91.0% | 82.8% | 17.2 kW | 17.2 kW | +1.8 kW |
| 2% | 90.0% | 90.0% | 81.0% | 19.0 kW | 19.0 kW | +3.6 kW |
| 3% | 89.0% | 89.0% | 79.2% | 20.8 kW | 20.8 kW | +5.4 kW |
| 4% | 88.0% | 88.0% | 77.4% | 22.6 kW | 22.6 kW | +7.2 kW |
| 5% | 87.0% | 87.0% | 75.7% | 24.3 kW | 24.3 kW | +9.0 kW |
| 6% | 86.0% | 86.0% | 74.0% | 26.0 kW | 26.0 kW | +10.7 kW |
| 7% | 85.0% | 85.0% | 72.3% | 27.7 kW | 27.7 kW | +12.4 kW |
| 8% | 84.0% | 84.0% | 70.6% | 29.4 kW | 29.4 kW | +14.1 kW |
| 9% | 83.0% | 83.0% | 68.9% | 31.1 kW | 31.1 kW | +15.8 kW |
| 10% | 82.0% | 82.0% | 67.2% | 32.8 kW | 32.8 kW | +17.4 kW |
* Reference Input Power: 100 kW | η nominal: 92%